COOPERATOREVENTS NEW YORK EXPO. TUESDAY NOV 19TH . JAVITS CONVENTION CENTER. REGISTER NOW!

Heating and Cooling Glossary of Terms

Heating and Cooling
A variety of HVAC technologies can be found in New York City's residential housing stock. Here's a look at some of the more common elements.Packaged Terminal Air Conditioner (PTAC) PTAC is the acronym for packaged terminal air conditioner. PTACs typically include self-contained heating and cooling components such as a compressor and electrical resistance heating intended for mounting through-the-wall to serve a room or single zone area. Packaged Terminal Heat Pump (PTHP) A PTAC capable of using the air conditioner refrigeration system in a reverse cycle or heat pump mode to provide heat.Steam Radiator A steam radiator is a heater consisting of a series of pipes for circulating steam or hot water to heat rooms or buildings. Electric Baseboard Heat A type of heating system that generates heat by passing current through a conductor, causing it to heat up. These systems are packaged as a baseboard heater, typically mounted on the floor along the baseboard of a room and often have a line-voltage thermostat dial control on the unit.Fan Coil A fan coil unit is comprised of a finned-tube coil, an insulated drain pan under the coil to collect condensate, a fan to move air through the coil, filters, and a cabinet to house these components. Typically fan coils are either located above ceilings and ducted to ceiling diffusers, or under windows using console units. Console units are sometimes ducted through the wall for ventilation air. Two-Pipe Fan Coil System A two-pipe fan coil system consists of a fan coil unit(s) with single coils, which are connected to two pipes (one supply pipe and one return pipe) that either provide hot water or chilled water to the fan coil. A building with a two-pipe system is either entirely in a heating mode or entirely in a cooling mode. It is not possible to cool some rooms while heating others.Four-Pipe Fan Coil System A four pipe system consists of a fan coil unit(s) with separate heating and cooling coils, as well as separate pairs of heating and cooling pipes. Hot water or chilled water is always available. The system is able to instantly switch from the heating mode to the cooling mode, or vice versa, and can provide heating to some rooms while simultaneously providing cooling to other rooms. Line-voltage Thermostat The typical line-voltage thermostat contains a bimetallic strip that bends as the temperature changes to close and open a switch. Refrigerant-tube or bulb thermostats use the change in refrigerant pressure as temperature changes to actuate a switch closure. Unlike low-voltage thermostats that carry very little current, line-voltage thermostats must carry the full current drawn by the heating or cooling system. This can generate considerable heat in the bimetallic element causing it to respond inaccurately.

Related Articles

Anti-cockroach icon, pest control, destruction of parasites, stop insect , black contour, isolated, white background

20% Of NY Metro Households Have Pest Problems

Aging Housing Stock Partly to Blame

Looking up at the beautiful windows of a New York City Building. Construction scaffolding / elevator

Dealing With Major Façade Projects

In Co-ops & Condos, the “F” Word is “Façade”

Air conditioner technician repairing central air conditioning system with outdoor tools

It's Getting Warmer...

Time to Service Your HVAC System